Skip to main contentSkip to solution

The magnification of a compound microscope in normal adjustment is 200. If the focal lengths of the objective and eye-piece are 1.0 cm and 2.0 cm, respectively, then the length of the tube is:

Solution

✅ Correct Option: 4

In normal adjustment the final image is at infinity, so the magnification is

M=Lfo⋅DfeM = \dfrac{L}{f_o} \cdot \dfrac{D}{f_e}

Here LL is the tube length and D=25D = 25 cm is the least distance of distinct vision.

200=L1.0×252.0200 = \dfrac{L}{1.0} \times \dfrac{25}{2.0}

L=200×225=16 cmL = \dfrac{200 \times 2}{25} = \boxed{16 \text{ cm}}


Option 3: 14.81 cm comes from using the formula for the final image at the near point, M=mo(1+Dfe)M = m_o\left(1 + \dfrac{D}{f_e}\right). That is not normal adjustment.