A coil is connected to a galvanometer G. Second coil is connected to a battery through a tapping key. The steady current in the coil produces a steady magnetic field. As coil is moved towards the coil , the galvanometer shows a deflection. To obtain a large deflection, one or more of the following steps can be taken:
(A) Use a rod made of soft iron inside the coil
(B) Connect the coil to a more powerful battery
(C) Move the arrangement of coil rapidly towards the coil
(D) hold the key pressed continuously
A coil is connected to a galvanometer G. Second coil is connected to a battery through a tapping key. The steady current in the coil produces a steady magnetic field. As coil is moved towards the coil , the galvanometer shows a deflection. To obtain a large deflection, one or more of the following steps can be taken:
(A) Use a rod made of soft iron inside the coil
(B) Connect the coil to a more powerful battery
(C) Move the arrangement of coil rapidly towards the coil
(D) hold the key pressed continuously
Solution
The deflection depends on the induced emf, . It is larger when the flux through is stronger and changes faster.
(A) A soft iron rod inside strengthens its magnetic field, so the flux linked with is larger.
(B) A more powerful battery gives a larger current in , so the field is stronger.
(C) Moving rapidly toward increases .
(D) Holding the key pressed only keeps the current steady. It does not change the flux through any faster, so it adds nothing to the induced emf. The relative motion of the coils is what produces the deflection.