Skip to main contentSkip to solution

A moving coil galvanometer has 100 equal divisions. Its current sensitivity is 20 divisions per mA and voltage sensitivity is 4 divisions per mV. To convert it into a voltmeter in which each division reads 1 V, the resistance needed to be connected in series with the coil will be :

Solution

✅ Correct Option: 2

Galvanometer resistance is the ratio of voltage sensitivity to current sensitivity, so G=current sensitivityvoltage sensitivityG = \dfrac{\text{current sensitivity}}{\text{voltage sensitivity}} inverted in the form G=V per divI per divG = \dfrac{V \text{ per div}}{I \text{ per div}}.

G=1/4 mV1/20 mA=5 ΩG = \dfrac{1/4 \text{ mV}}{1/20 \text{ mA}} = 5\ \Omega

Full-scale current for 100 divisions:

Ig=10020=5 mA=5×10−3 AI_g = \dfrac{100}{20} = 5 \text{ mA} = 5 \times 10^{-3} \text{ A}

Full-scale voltage required (1 V per division):

V=100×1=100 VV = 100 \times 1 = 100 \text{ V}

For a voltmeter, V=Ig(G+R)V = I_g (G + R)

G+R=1005×10−3=20000 ΩG + R = \dfrac{100}{5 \times 10^{-3}} = 20000\ \Omega

R=20000−5=19995 ΩR = 20000 - 5 = \boxed{19995\ \Omega}