Skip to main contentSkip to solution

A transformer has 1000 turns in the primary and 2000 turns in its secondary winding. The primary voltage is 200 V and the load across the secondary is 100 Ω100\ \Omega. If the transformer is assumed to be ideal, then the value of current in the primary is

Solution

✅ Correct Option: 4

For an ideal transformer, VsVp=NsNp\dfrac{V_s}{V_p} = \dfrac{N_s}{N_p} and VpIp=VsIsV_p I_p = V_s I_s.

Vs=200×20001000=400 VV_s = 200 \times \dfrac{2000}{1000} = 400 \text{ V}

Is=VsR=400100=4 AI_s = \dfrac{V_s}{R} = \dfrac{400}{100} = 4 \text{ A}

Ip=Is×NsNp=4×2=8.0 AI_p = I_s \times \dfrac{N_s}{N_p} = 4 \times 2 = \boxed{8.0 \text{ A}}