The current sensitivity of a moving coil galvanometer can be increased by:
The current sensitivity of a moving coil galvanometer can be increased by:
Solution
The current sensitivity of a moving coil galvanometer is the deflection per unit current:
where is the number of turns, is the coil area, is the magnetic field and is the torsional constant of the spring. Sensitivity is inversely proportional to , so a spring with a lower torsional constant gives a larger deflection for the same current.
Options 2 and 3: decreasing the radius reduces , and decreasing the turns reduces , so both lower the sensitivity.
Option 1: a stiffer spring (higher ) reduces the deflection per unit current.
Increasing also raises the voltage sensitivity only if the resistance does not rise as fast, and since , voltage sensitivity does not improve when is increased.
Related questions:
2025: 15 May Shift 2