The current sensitivity of a moving coil galvanometer can be increased by:

Solution

✅ Correct Option: 4

The current sensitivity of a moving coil galvanometer is the deflection per unit current:

θI=NABk\dfrac{\theta}{I} = \dfrac{NAB}{k}

where NN is the number of turns, AA is the coil area, BB is the magnetic field and kk is the torsional constant of the spring. Sensitivity is inversely proportional to kk, so a spring with a lower torsional constant gives a larger deflection for the same current.


Options 2 and 3: decreasing the radius reduces AA, and decreasing the turns reduces NN, so both lower the sensitivity.

Option 1: a stiffer spring (higher kk) reduces the deflection per unit current.

Increasing NN also raises the voltage sensitivity only if the resistance does not rise as fast, and since R∝NR \propto N, voltage sensitivity NABkR\dfrac{NAB}{kR} does not improve when NN is increased.